Innovative commercial engineering software production and consulting firm Setting the standard in Thermal and Aerodynamic Analysis and Simulation Software
 
Series Piping Systems
     
 

INSTED Heat Exchanger and Thermodynamic Analysis Module

Capabilities

Rating (Performance Analysis)
Calculation of flow rate
Calculation of pressure loss
System curve generation
Prediction of cavitations
Calculation of power/energy
Calculation of pipe diameter
Features
Supports up to 1000 pipes
Supports up to 500 loss types per pipe
Grouping into pipe types makes the analysis of complicated systems
    very easy (pipes of the same type have equal diameter and
    roughness values)
Module Intergration
INSTED/Database modules used:

Fluid thermophysical properties or fluid viscosity and density
Pipe thermal conductivity
Fouling resistance
Pipe schedules
Roughness data
K-factor for loss type

Links to the Fin Analysis program for calculation of fin resistance and efficiency

Program Interaction

Required Input for Rating Analysis
Velocity at inlet and outlet
Elevation at inlet and outlet
Pressure at inlet and outlet
Fluid density
Fluid viscosity
Total flow rate
Number of pipes, pipe types, and loss types.
For each pipe type:
Pipe diameter
Pipe roughness
For each loss type:
Loss type K-factor
For each pipe:
Length of pipe
Pipe type
Number of loss components
Loss component type for each loss component
Results from Rating Analysis
Flow rate
Pressure loss
Power/Energy
Likelihood of occurence of cavitation
System curve
For each pipe:
Velocity
Pressure drop

Graphs

Plots graph of system curve
Plots graph of pump curve if user provides data points
Computes the intersection of system and pump curve

Additional Result Format:

Printable result summary sheet.

Click to return to INSTED home page.